Fire rated aluminium is now a baseline specification on most UK commercial builds, not an optional upgrade. Stricter façade legislation and post-Grenfell scrutiny have made certified fire resistance a non-negotiable part of any aluminium door, window, curtain wall or cladding project. This article explains what drives that demand, how the performance classification system works, and how LSF Commercial’s certified team delivers compliant solutions without compromising design.

Why commercial buildings need fire rated aluminium systems

For external wall systems and cladding, the baseline is now non-combustible material classified A1 or A2-s1, d0 to EN 13501-1, supported by full-system test evidence. Buildings over 18 metres also trigger BS 8414 full-system testing as an alternative compliance route. Scotland applies these restrictions from 11 metres upwards.

Compliance is not limited to new builds. Where existing cladding is found to contain non-compliant materials, building owners face enforcement notices and mandatory remediation. Fire risk assessments under the Regulatory Reform (Fire Safety) Order 2005 must now include external walls and cladding systems.

Aluminium meets these demands precisely because it combines light weight with long-term structural performance. Fire rated aluminium profiles achieve integrity and insulation ratings from 30 to 120 minutes under BS EN 1634-1 while the low profile mass keeps structural loads on the host frame manageable.

How fire resistance ratings and performance classes work

Understanding the classification system is the starting point for correct specification. Ratings are expressed using three performance values:

Code What it measures
**E (Integrity)** Prevents passage of flames and hot gases
**W (Radiation)** Limits heat radiated through the assembly
**I (Insulation)** Limits temperature rise on the non-fire side

The numbers 30, 60, 90 and 120 indicate minutes of resistance. So EI60 means the system prevents flame, smoke and heat transfer for a full 60 minutes.

There are two primary classifications in use:

  • E-rated (integrity only): Stops flames but allows radiant heat to pass. Typically used where occupants are not in direct line of sight of the glazed element.
  • EI-rated (integrity and insulation): Provides the same flame and smoke resistance and limits heat transfer. Required on escape routes and compartment boundaries where proximity to occupants is a factor.

Proper installation is as important as the product itself. A correctly specified door or screen will fail to perform as rated if it is not installed in accordance with the tested configuration. Every component, frame, glass, intumescent seals and hardware, must be supplied and fitted as a system, not assembled from separate sources.

Curtain walling, glazing and cladding: integrating fire performance

commercial building

Fire rated aluminium performs across the full range of façade elements, not just doorsets. This is where its architectural value becomes clear.

Fire rated curtain wall systems incorporate fire resistant glazing, cavity fire barriers and structural aluminium profiles to prevent fire spread between floors and compartments. These solutions suit high-rise commercial developments where a continuous glazed elevation must still meet compartmentation requirements.

Fire rated cladding must be considered as a complete assembly. A panel rated A2-s1,d0 can still become non-compliant if installed over a prohibited foam backing or without correctly installed cavity barriers at every floor level. Specifiers must verify third-party fire certificates for the exact colour, thickness and sub-structure configuration they intend to use.

Fire rated windows and screens can be integrated with standard aluminium window systems across the same elevation, maintaining a flush, consistent sightline while meeting Approved Document B requirements at openings in fire-separating elements.

What does certified fabrication look like in practice?

Certification separates a compliant supply chain from one that only looks compliant on paper. LSF Commercial is certified to manufacture and install Schüco 30- and 60-minute fire rated aluminium systems. The team also works with Alufire systems, a specialist producer that has focused exclusively on fire resistant aluminium solutions since 2004, and uses fire resistant glass from Vetrotech by Saint-Gobain.

LSF Commercial’s fire rated range covers doors, windows, screens and curtain walling systems, with ratings from 30 minutes up to 90 minutes depending on project requirements. All products comply with current British Standards and building regulations, and each installation includes full certification and documentation.

From the initial project brief through to installation, our team manages the process end-to-end from our manufacturing facility in Rainham, Essex covering design, fabrication and on-site installation with a single point of accountability.

Frequently asked questions

What fire rating do I need for a commercial entrance door?

Office doors on internal escape routes typically require EI30 (30-minute insulation). Stairs, lift shafts and basement areas generally demand EI60. The correct rating is determined by your fire risk assessment and the building’s fire strategy, not by building type alone. LSF Commercial’s fire rated door range is available in 30, 60, 90 and 120 minute ratings.

Do fire regulations apply to refurbishment projects?

Yes. If you are adding or replacing cladding or glazed elements on an existing building, the same regulations apply. The regulatory requirement is set by building type and height, not by whether the work is new construction or a refurbishment. Buildings where existing cladding is found to be non-compliant may be subject to enforcement action requiring full replacement.

Can fire rated aluminium systems be aesthetically specified?

Yes. Fire rated aluminium profiles are available in a wide range of RAL powder coat finishes, and systems can be designed to produce narrow sightlines indistinguishable from standard commercial aluminium. LSF Commercial works with architects and specifiers to match fire rated and non-fire rated elements across the same elevation, maintaining design coherence without compromising performance.

Ready to specify fire rated aluminium for your next project? Contact the LSF Commercial team online or call 01708 552 225 for certified system advice, compliance documentation and a project quote.

Contact Us

If you'd like to find out more about working with LSF Commercial as your dedicated aluminium specialist, get in touch today. Whether you're working on a commercial refurbishment project, a new build development, or retail premises overhaul, we can help. Simply enter your details into the contact form and we'll get back to you as quickly as possible. With LSF Commercial as your project lead, you know you're in safe hands.






    Upload your images or drawings to help with your enquiry. Use the upload button to upload multiple documents (1.5mb maximum
    file size).


    By submitting your details you confirm that you agree to the storing and processing of your personal data by LSF Commercial as described in the privacy statement